G1000/DA 40 System Maintenance Manual
Page 7-15
190-00303-03
Revision 6
7.4.2 GEA 71 Configuration Loading
1.
Insert the correct G1000/DA 40 SW Loader Card (see Appendix A) into top slot of PFD.
2.
Start the G1000 system in Configuration mode, if not already in Configuration mode.
3.
At the PFD, go to the Configuration Upload page using the FMS knob:
4.
Activate cursor and highlight ‘GEA 1’ in the FILE LIST field.
5.
Press the LOAD softkey.
6.
Select YES and press the ENT key to acknowledge the following prompt:
7.
Monitor the status of the upload. When the upload is finished, press the ENT key to acknowledge
the following confirmation:
8.
View the SUMMARY field and ensure that all items are ‘COMPLETE’, then de-activate the
cursor.
9.
Go to the System Status page.
10.
Activate the cursor and highlight ‘GEA1 – GIA1’ and ‘GEA1 - GIA2’ in the LRU window.
11.
Verify that the reported part number and version of the software file matches the data in
Appendix A.
12.
Continue to the GEA 71 Test procedure.