G1000/DA 40 System Maintenance Manual
Page 4-9
190-00303-03
Revision 6
7.
Press the L RESET softkey. Press ENTER to acknowledge the following prompt:
8.
Ensure that the CAL VAL indication for the Left 1 Sub-Tank is stable.
9.
Press the L EMPTY softkey.
10.
Press the R RESET softkey. Press ENTER to acknowledge the following prompt:
11.
Ensure that the CAL VAL indication for the Right 1 Sub-Tank is stable.
12.
Press the R EMPTY softkey.
13.
Observe the CAL VAL indications for both Right 1 and Left 1 Sub-Tanks and record the readings
in the following tables. The CAL VAL values should fall between –1 and 0 as shown in the
following examples:
LEFT 1 SUB-TANK
Calibrated Value (CAL VAL) Range
Actual
Useable
Fuel
Minimum Allowed
Indication
Maximum Allowed
Indication
Record Actual Indicated
CAL VAL
Here
Is CAL VAL Within
Specified Range?
Yes / No
0 -1
0
5 4
6
RIGHT 1 SUB-TANK
Calibrated Value (CAL VAL) Range
Actual
Useable
Fuel
Minimum Allowed
Indication
Maximum Allowed
Indication
Record Actual Indicated
CAL VAL
Here
Is CAL VAL Within
Specified Range?
Yes / No
0 -1
0
5 4
6
14.
Fill each fuel tank with 5 gallons ± 0.1 gallons usable fuel.
15.
Allow the system to stabilize before taking readings.