![Garmin Diamond DA40 Maintenance Manual Download Page 71](http://html1.mh-extra.com/html/garmin/diamond-da40/diamond-da40_maintenance-manual_4182198071.webp)
G1000/DA40 System Maintenance Manual
Page 5-9
190-00303-03
Revision 6
MESSAGE ADVISORY Alerts
Message Advisory
Solution
PFD FAN FAIL – The cooling fan for the PFD is
inoperative.
MFD FAN FAIL – The cooling fan for the MFD is
inoperative.
GIA FAN FAIL – The cooling fan for the GIAs is
inoperative.
Ensure that the CDU FAN and/or AV FAN circuit breakers are
closed.
Check cooling fan wiring.
Replace cooling fan. Refer to Figure 2-2 and/or Figure 2-7
for installation drawings.
From this point forward, all other message advisory alerts are standard to the G1000
system and are not specific to the DA 40. Messages are grouped according to LRU.
5.4
GDU 1040 Troubleshooting
5.4.1 GDU 1040 Common Problems
Symptom Recommended
Action
Display will not track photocell
Check display lighting settings on the Main Lighting page:
9
If problem persists, replace defective unit.
Keypad/bezel will not track photocell
Check keyboard lighting settings on the Main Lighting page:
9
If problem persists, replace defective unit.
Display will not track dimmer bus
Check display lighting settings on the Main Lighting page.
Switch MFD and PFD:
9
If problem follows unit, replace defective unit.
Keypad/bezel will not track dimmer
bus
Check keyboard lighting settings on the Main Lighting page.
Switch MFD and PFD:
9
If problem follows unit, replace defective unit.
5.5
GDU 1040 Alerts
5.5.1 Software/Configuration Alerts
Failure Message
Cause
Solution
SW MISMATCH – GDU software
version mismatch. Xtalk is off.
The system has found the PFD
and MFD software versions do not
match.
MANIFEST – PFD1 software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in the PFD.
MANIFEST – MFD software
mismatch. Communication
Halted.
The system has detected an
incorrect software version loaded
in MFD.
Load correct software version. See
Section 7.1 for GDU 1040 Software
Loading procedure.
MFD1 CONFIG – configuration
error. Config service req’d.
PFD1 CONFIG – configuration
error. Config service req’d.
A configuration mismatch has
occurred between the display and
the Master Configuration Module.
Reconfigure MFD and/or PFD as
described in Section 7.1.2.
If unable to reconfigure, replace
defective master configuration
module as described in
Section 6.8.
5.5.2 Database
Alerts
Failure Message
Cause
Solution
MFD1 DB ERR – MFD1 aviation
database error exists.
The MFD has encountered an
error in the Jeppesen aviation
database.
Reload Jeppesen database.
Replace the MFD.
NOTE