G1000/DA40 System Maintenance Manual
Revision 6
190-00303-03
Page B-10
B.6.3
GRS 77 AHRS Software
1.
Highlight the GRS77 software file. Ensure that the GRS to GIA data path appears in the LRU
field as shown:
2.
Press the LOAD softkey.
3.
Select YES and press the ENT key to acknowledge the following prompt:
4.
The software for the GRS 77 AHRS begins to load. Monitor the upload status as it progresses:
5.
After the files finish loading, press the ENT key to acknowledge the following prompt:
6.
Check the SUMMARY field to ensure the load is ‘COMPLETE’.