7.8.1 System
Communication Hierarchy
The following criteria must be satisfied to be able to perform these desired operations:
Desired Operation
Criteria for Success
Load Software to GDU 1040 MFD or PFD Displays
•
G1000/DA 40 SW Loader Card must be inserted in
top slot for each display to be loaded.
•
CLR & ENT keys must be held during power up of
display.
•
Power on only one display at a time during
software loading.
Load AIRFRAME, SYSTEM, MFD1, PFD1, and
MANIFEST configuration files to MFD and PFD
•
G1000/DA 40 SW Loader Card must be inserted in
top slot of PFD.
•
PFD and MFD must be powered on.
•
PFD and MFD must have correct software.
Load Software/Configuration files to GIA 63s
•
G1000/DA 40 SW Loader Card must be inserted in
top slot of PFD.
•
G1000 system must be powered on.
•
PFD and MFD must have correct software.
•
PFD and MFD must be successfully configured
with AIRFRAME, SYSTEM, MANIFEST, MFD1,
and PFD1 configuration files.
Load Software/Configuration files to:
- GMA 1347
- GDC 74A
- GEA 71
- GRS 77 (software only)
- GMU 44 (software only)
- GTX 33
•
G1000/DA 40 SW Loader Card must be inserted
into PFD top slot.
•
G1000 must be powered on.
•
PFD and MFD must have correct software and
configuration settings.
•
GIA 63s must have correct software.
•
GIA 63s must be successfully configured with GIA1
and GIA2 configuration files.
•
Data path from GIA1 to each LRU must be
operational.