G1000/DA40 System Maintenance Manual
Page B-3
190-00303-03
Revision 6
B.2
MFD & PFD Software Load
1.
Remove power to the MFD and PFD by pulling the MFD and PFD circuit breakers.
2.
Insert the correct G1000/DA 40 Card Loader (see Appendix A) into the MFD top card slot.
3.
While holding the ENT key on the MFD, restore power by closing the MFD circuit breaker.
4.
When the words
appear in the upper left corner of the MFD,
release the ENT key.
5.
Press the ENT key to acknowledge the following prompt:
6.
The following screen is displayed.
7.
New software is loaded to the MFD. When complete, the MFD starts in configuration mode.
8.
Remove the G1000/DA 40 Card Loader from the MFD and insert it into the top card slot on the
PFD. Repeat Steps 3 through 7 for the PFD.
9.
When PFD update is complete, it starts in the configuration mode. Do not remove power.
For the rest of the software/configuration procedure, do not operate the MFD while
loading software or configuration files unless specifically instructed to do so. A failed or
cancelled load may result.
IMPORTANT