APPENDIX 4 ALERT LIST
AP-23
190
3
535
AIS Target Acti-
vate 100%
Warning/
A
100% of capacity
for active AIS is
used.
The number of ac-
tive AIS target be-
came 100% of its
limit. Change the
unnecessary tar-
gets to sleep
mode.
30001
17
073
Processor Unit
CPU Temp High
Caution/B
CPU temperature in
processor unit ex-
ceeds threshold.
Turn off Processor
Unit. If same error
occurs after a few
minutes, contact
FURUNO.
30001
19
075
Processor Unit
CPU Board Temp
High
CPU temperature in
processor unit ex-
ceeds threshold.
Turn off Processor
Unit. If same error
occurs after a few
minutes, contact
FURUNO.
30001
23
079
Processor Unit
Fan1 Rotation
Speed Lowering
Rotation speed of
fan1 in processor
unit is below thresh-
old.
If the error fre-
quently occurs,
contact FURUNO
and inform fre-
quency of
occurrence.
30001
26
089
Processor Unit
CPU board Battery
Power Error
CPU board battery
voltage in processor
unit is out of thresh-
old.
Turn off Processor
Unit. If same error
occurs after a few
minutes, contact
FURUNO.
30001
27
090
Processor Unit
CPU board Core
Power Error
CPU board core
voltage in processor
unit is out of thresh-
old.
Turn off Processor
Unit. If same error
occurs after a few
minutes, contact
FURUNO.
30001
31
400
Network Printer
Not Available
When executing
printout, network
printer is not recog-
nized, network
printer connection is
interrupted, or print-
er error such as pa-
per shortage, paper
jam and run out of
ink occurs.
Check that the
printer is connect-
ed to network or
printer errors such
as paper shortage,
paper jam and run
out of ink does not
occur.
30001
32
401
Local Printer Not
Available
When executing
printout, local print-
er is not recognized,
local printer con-
nection is interrupt-
ed, or printer error
such as paper
shortage, paper jam
and run out of ink
occurs.
Check that the
printer is connect-
ed to network or
printer errors such
as paper shortage,
paper jam and run
out of ink does not
occur.
ALF
ALR
Alert name
Priority/
Category
Meaning
Remedy
No.
Inst.*
No.
Summary of Contents for FMD3100
Page 36: ...1 INTRODUCTION 1 20 This page is intentionally left blank ...
Page 70: ...2 OPERATIONAL OVERVIEW 2 34 This page is intentionally left blank ...
Page 128: ...5 VECTOR S57 CHARTS 5 12 This page is intentionally left blank ...
Page 140: ...7 C MAP BY JEPESSEN CHARTS 7 6 This page is intentionally left blank ...
Page 206: ...11 HOW TO MONITOR ROUTES 11 16 This page is intentionally left blank ...
Page 230: ...13 TRACKED TARGET TT FUNCTIONS 13 10 This page is intentionally left blank ...
Page 244: ...14 AIS TARGET FUNCTIONS 14 14 This page is intentionally left blank ...
Page 250: ...15 AIS SAFETY NAVTEX MESSAGES 15 6 This page is intentionally left blank ...
Page 294: ...19 RECORDING FUNCTIONS PLAYBACK FUNCTIONS 19 14 This page is intentionally left blank ...