6. 9.6k DATA COMMUNICATIONS
6-25
6.8
S Registers
ATSm=<n>
•
Stores the value “n” in the S register located in the “m”th
position.
ATSm?
•
Reads the value from the S register located in the “m”th
position.
Register name
S0
S1
S2
S3
▲
S4
▲
S5
▲
S6
S7
S8
S10
S12
Description
Specifies whether an incoming call is automatically accepted.
Setting range: 0 Not automatically accepted
1-255 Automatically accepted
(Reserved)
(Reserved)
Specifies a CR code.
Setting range: 0-127
Specifies a LF code.
Setting range: 0-127
Specifies a BS code.
Setting range: 0-32, 127
(Reserved)
(Reserved)
(Reserved)
(Reserved)
(Reserved)
Initial value
0
-
-
13
10
8
-
-
-
-
-
▲
Note:
Do not modify any value stored in the reserved S registers and the S
registers that are not listed here. The operation under any modified value is
not covered by our warranty.