BX900 S2
Upgrade and Maintenance Manual
205
Appendix
13.5 Minimum startup configuration
If the system unit does not start up or other problems occur, it may be necessary
to take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components:
Ê
Shut down the system unit as described in section
"Shutting down the
system unit" on page 49
.
Ê
Remove the AC power cords from the cable ties and disconnect them from
the PSUs as described in section
"Disconnecting the power cords" on
page 49
.
Ê
Take the system down to its minimum startup configuration.
Ê
Reconnect the AC power cords to the PSUs and secure them with cable ties
as described in section
"Connecting the system unit to the mains" on
page 50
.
Ê
Switch on the server as described in section
"Switching on the system unit"
on page 52
.
Ê
Login to the management blade web interface, see section
"Accessing the
management blade web interface" on page 44
.
Field Replaceable Units (FRU)
Component
Notes and reference
BX900 S2 system unit
enclosure
1 server blade
Installed in slot 1, see section
"Cooling
requirements" on page 88
.
1 management blade
3 PSUs
Installed in slots PSU 2, 3, 6, see section
"Cooling requirements" on page 88
.
1 connection blade
Table 9: Minimum startup configuration - components