Figure 48: Installing/removing the management blade battery
Ê
Press the locking springs in the direction of the arrow (1) so that the lithium
battery is ejected from its holder, and remove the battery (2).
Ê
Place the new battery of the same type in the holder (3) and press it in the
direction of the arrow (4) until it clicks into place.
Ê
Close the management blade cover in the opposite order to that described
above, see
"Opening the management blade" on page 149
.
Ê
Reinstall the management blade in the system unit.
A management blade is installed in the same way as a single-width
connection blade as described in section
"Installing a single-width
connection blade" on page 113
.
9.4.4
Concluding steps
Perform the following procedures to complete the task:
Ê
Verify the time settings of the management blade as described in section
"Verifying the management blade time settings" on page 70
.
Ê
If applicable, close the rack door as described in section
"Closing the rack
door" on page 60
.