BX900 S2
Upgrade and Maintenance Manual
189
Appendix
13.3.3.2 Connection Blade GbE Switch/IBP 36/12 (SB11A)
Figure 83: Connection Blade GbE Switch/IBP 36/12
1
ID indicator (blue)
Lit:
ID indicator was activated via the management blade
Dark:
Normal operation
2
Status indicator (green/orange)
Lights up green: power supply is supplied to the connection blade.
Dark: power supply is not supplied to the connection
blade.
Lights up
orange:
Switch error
Dark:
Power supply interrupted
A
1-Gbit Ethernet ports for SFP modules for connecting fiber-optic or copper
cables (4x, with two integrated status LEDs each)
3 (ERR)
Error indicator (orange)
Dark:
No SFP+ transceiver error
Lit:
SFP transceiver error
Flashes:
SFP module not supported
4 (LINK)
LAN connection indicator (green)
Lit:
SFP transceiver connection available
Flashes:
SFP transceiver connection active
Dark:
SFP transceiver connection not available or deactivated