5.2.1.3
Updating the management blade firmware via recovery flash
Ê
Open the management blade, as described in section
"Opening the
management blade" on page 149
.
Ê
Enter recovery mode using the DIP switch, see section
"Management Blade
Settings" on page 204
.
Ê
Close the management blade in the opposite order to that described in
section
"Opening the management blade" on page 149
.
Ê
Install management blade into the system unit,
"Installing the management
blade" on page 145
.
Ê
Connect the FST to the serial port of the management blade, see section
"Connectors on the management blade" on page 183
.
Ê
Open a Hyperterminal session using the following parameters:
The welcome screen of the recovery console menu is displayed.
⎜
(1) Upgrade Firmware from Network
⎥
⎜
(2) Network Parameters
⎥
⎜
----------------------------------------
⎥
⎜
Choose: 2
⎥
⎜
⎥
⎜
⎥
⎜
⎥
Figure 12: Recovery console menu
Ê
Enter 2 to open the
Network Parameters
menu.
Ê
Select
1
to set the IP Address of the management blade management LAN
port.
Ê
Enter
2
to set the IP address of the TFTP server.
Ê
Enter
3
to set the gateway address of management LAN port.
Bits per second
115200
Data bits
8
Parity
None
Stop bits
1
Flow control
Xon/Xoff
Table 4: COM parameters