5.2.9
Verifying power consumption
I
This task applies only, if a PSU must be replaced, which has not failed
completely.
Ê
Login to the management blade web interface, see section
"Accessing the
management blade web interface" on page 44
.
Ê
Open the
Information/Operation – Operation – Power Management
menu,
select the
Configuration
tab and scroll to the
Power Consumption Options
box.
– If a redundancy mode is selected in the
Redundancy
pull down (for
example 3+1) you can replace the PSU with no problems.
– If
No Redundancy
is selected in the
Redundancy
pull down and if the
Remaining Output Power
is less than ca. 3200 W, you must shut down
some server blades before replacing the PSU.
I
The
Remaining Output Power
value is displayed in the status frame
of the management blade web interface.