3. OUTDOOR UNIT & BRANCH BOX
BRANCH BOX
1-3.
Model name
UTP-PU03A (Primary)
UTP-PU03B (Secondary)
Casing color
Paintingless
Paintingless
Connectable indoor unit
1 to 3 Units
1 to 3 Units
Max. combination
Btu/h
62,000
62,000
Min. combination
Btu/h
7,000
7,000
Power source
1ø 208/230V 60Hz
1ø 208/230V 60Hz
Available voltage range
187-264V
187-264V
Power consumption
W
10
10
Running current
A
0.05
0.05
Refrigerant type
R410A
R410A
Dimensions
(H × W × D)
Net
in. (mm)
7-5/8 × 17 × 14-5/8 (195×433×370)
7-5/8 × 17 × 14-5/8 (195×433×370)
Gross
10 × 36-5/8 × 17-1/8 (255×929×434)
10 × 36-5/8 × 17-1/8 (255×929×434)
Weight
Net
lbs (kg)
20 (9)
20 (9)
Gross
29 (13)
29 (13)
Connection
pipe
Size
Liquid
in. (mm)
Main : 3/8 (9.52) ×1, Branch : 1/4(6.35)×3
Main : 3/8 (9.52) ×1, Branch : 1/4(6.35)×3
Gas
Main : 5/8(15.88)×1, Branch : 1/2(12.7)×3
Main : 5/8(15.88)×1, Branch : 1/2(12.7)×3
Method
Flare
Flare
Operation range
°F (°C)
5 to 115 (-15 to 46)
5 to 115 (-15 to 46)
%RH
80 or less
80 or less
Note : Specifications are based on the following conditions.
Power source of specifications : 230V.
- (03 - 03) -
OU
TDOOR
UNITS
OU
TDOOR
UNITS
Summary of Contents for ARU12RLF
Page 3: ...1 GENERAL INFORMATION DTR_BMU001E_03 CHAPTER01 2010 08 25 Hybrid Flex Inverter System ...
Page 18: ...2 MODEL SELECTION DTR_BMU001E_04 CHAPTER02 2010 10 04 Hybrid Flex Inverter System ...
Page 38: ...3 OUTDOOR UNIT BRANCH BOX Hybrid Flex Inverter System DTR_BMU001E_04 CHAPTER03 2010 10 04 ...
Page 58: ...4 INDOOR UNITS Hybrid Flex Inverter System DTR_BMU001E_05 CHAPTER04 2010 11 12 ...
Page 116: ...5 CONTROL SYSTEM DTR_BMU001E_04 CHAPTER05 2010 10 04 Hybrid Flex Inverter System ...
Page 152: ...6 SYSTEM DESIGN DTR_BMU001E_04 CHAPTER06 2010 10 04 Hybrid Flex Inverter System ...
Page 287: ...7 OPTIONAL PARTS Hybrid Flex Inverter System DTR_BMU001E_03 CHAPTER07 2010 08 25 ...