Using Auto-SYNC for Digital Input Connections
232 TIMS MVP
™
Setup and Configuration Guide
In the next example, the lines are broken and distorted. In order to adjust the image, change the
Field Polarity.
Figure 127: Example of video image with the improper Field Polarity setting
Tips:
Field Polarity
Fields are jagged in interlaced image
–
select Odd Field Up
Vertical Sync Type
Flagging at the top of the image
–
select Block as source
Miscellaneous Information
▪
One frame is one screen of visible data
▪
A frame of data contains visible AND non-displayed information, image blanking and
synchronization
▪
Interlaced signals are comprised of an Odd and Even field of separate Odd and Even
lines
▪
Two fields comprise a frame
▪
Non-interlaced, also called progressive scan, is one frame of sequential lines
▪
Fields must be paired properly and “ordered” properly
Summary of Contents for TIMS 2000 EN
Page 1: ...060000 91 Rev 1...