Table 10-2. Custom Limit Settings for OTDR Tests
Setting Description*
Length
Enter a maximum length for the cabling.
Reflective Event Loss
Enter a maximum value for connector loss. A typical value is 0.75 dB.
Non-reflective Event Loss
Enter a maximum value for splice loss. A typical value is 0.3 dB.
Overall Loss
Enter a maximum value for the loss of all components and fiber in the cabling. You
may also enter a minimum loss value if receiver saturation is an issue in the
installation.
Segment Attenuation Coeff
Enter a maximum value of attenuation per kilometer for a fiber segment in the
cabling.
Note
The segment attenuation coefficient for shorter segments (50 m to 500 m,
depending on wavelength and fiber characteristics) may not be measurable.
Overall Attenuation Coeff
Enter a maximum value of attenuation per kilometer for the entire length of the
cabling.
Event Reflectance
Enter a maximum reflection value for a single event.
*
Minimum values are usually not used, but are available for special situations.
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...