Table 6-10. Diagnosing Loss/Length Test Failures (cont.)
Loss is negative.
•
The connections to the tester were disturbed after referencing.
•
The fiber ends were dirty during referencing.
•
There was a kink in a reference reference test cord during referencing.
•
The connectors were not properly aligned during referencing.
•
Some other problem caused a bad reference value.
If loss is negative, set the reference again and retest the cabling.
A known length of cable measures too long or too short.
•
The wrong fiber type is selected on the
Cable
tab in Setup.
•
The index of refraction needs adjustment. Change n on the
Cable
tab in Setup.
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...