OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
6-20
Running the Test in Smart Remote Mode
W
Caution
If you disconnected the reference test cords
from the tester’s or remote’s output, you must
set the reference again to ensure valid
measurements.
1
Verify that the settings described in Table 6-1 are
appropriate. Let the testers warm up for 5 minutes.
2
Set the main tester to loss/length mode: On the
HOME
screen, press
A
Change Test
; then select
Loss/Length
.
3
Clean the connectors on the cabling to be tested;
then connect the tester to the cabling as shown in
Figure 6-7.
For auto-incrementing fiber IDs, connect the fiber
with the lower ID to the main tester’s INPUT port.
For auto-incrementing fiber IDs with bi-directional
testing, connect the fiber with the lower ID to the
main tester’s OUTPUT port.
4
Press
T
to start the loss/length test.
5
If
Open
or
Unknown
appears as the status, try the
following:
•
Verify that all connections are good.
•
For an OptiFiber smart remote verify that the
remote tester is set to
Remote
on its
Loss/Length
tab in Setup.
•
Verify that the remote tester is still active. For an
OptiFiber smart remote you may need to press
A
Start
to reactive the tester.
•
Try different connections to the cabling until
the test continues. See “Using FindFiber in Smart
Remote Mode” on page 6-43 for details on
FindFiber messages.
•
Use a visible light source to verify fiber
continuity.
6
To save the results, press
s
, select or create a
fiber ID for the INPUT fiber; then press
s
. Select
or create a fiber ID for the OUTPUT fiber; then press
s
again.
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...