Using the OTDR
Looking at OTDR Test Results
3
3-27
A
Reflective event caused by the OTDR connection.
B
Reflective event caused by the first connection in the
cabling. This trace was produced using launch fiber
compensation, so the end of the launch fiber is marked
with a dashed line.
C
Loss event caused by a fusion splice.
D
Small reflective event caused by a mechanical splice.
E
Reflective event caused by the last connection in the
cabling. The dashed line marks the end of the fiber
under test and the beginning of the receive fiber.
F
Reflective event caused by the end of the receive fiber.
G
Overall loss of the cabling. Since launch and receive
fiber compensation was used, the overall loss excludes
the loss of the launch and receive fibers.
See “Diagnosing OTDR Test Failures” on page 3-51 for
descriptions of faults on fiber cabling.
Figure 3-14. Typical OTDR Trace Features (cont.)
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...