OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
3-36
Table 3-4. Event Types (cont.)
Event Possible
Causes and Solutions
WEAK SIGNAL
The signal is attenuated below
the background noise level
before the end event is reached.
No fiber is attached to the OTDR port, the fiber is too short, or there is a bad connector
or broken fiber somewhere near the tester. May also occur if the fiber has very high
loss, or if the tester is in Manual OTDR mode and the
PULSE WIDTH
is too narrow.
If the OTDR trace and event table show that the fiber is very short, check for bad
connections and broken fibers within a few meters of the tester.
NO FIBER
No fiber is attached or the fiber is
too short to measure.
No fiber is attached to the OTDR port, the fiber is too short, or there is a bad connector
or broken fiber somewhere near the tester.
Check for bad connections and broken fibers within a few meters of the tester.
NO SIGNAL
There is a problem with the
module.
If this continues to occur, contact Fluke Networks for assistance.
-continued-
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...