Using the OTDR
Diagnosing OTDR Test Failures
3
3-53
Table 3-7. Diagnosing Faults on OTDR Traces
Large reflective event with high loss (top), excessive tailing (middle), or a hook on the falling edge of
the trace (bottom). May be identified as an end event though it occurs before the end of the cabling.
May be caused by the following:
•
A dirty, scratched, cracked, misaligned, or unseated connector. Misaligned or unseated
connectors can also cause large reflections that produce ghosts. Bad connectors should be
cleaned, repolished, or replaced. A hook, as shown in the bottom example, can occur when a
large reflection causes the OTDR detector’s gain to become non-linear.
•
A good connector with a sharp bend or crack within its deadzone. If the cable is tightly bent the
tester may indicate a break, especially at longer wavelengths or in Manual OTDR mode with
smaller resolution settings. Use a visual fault locator to precisely locate the fault.
•
A crack in the fiber. Use a visual fault locator to precisely locate the fault.
•
A connection between mismatched fibers (different backscatter coefficients, core sizes,
numerical apertures, or other parameters). The top example could be caused by a larger core
(on the left) connected to a smaller core.
-continued-
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...