3. Commissioning
3-9
Festo P.BE-CPX-FVDA-P2-EN en 1209NH English
3.5
Setting the CPX module parameters
The characteristics of the output module CPX-FVDA-P2 can be
parametrised. Parameters that influence diagnostic or error
messages refer only to the diagnostic system of CPX and not
on the diagnostic channels of the safety protocol.
Additional information on parametrisation can be found in the
CPX system description P.BE-CPX-SYS-… or in the description
of the CPX bus node.
The following table provides an overview of the available CPX
module parameters of the output module.
Overview of module parameters CPX-FVDA-P2
Function number
1)
Bit
Module parameters
Presetting
4828 + m * 64 +
0
0, 1
2
3 ... 7
Reserved
Monitoring of supply voltage U
VAL
Reserved
–
Active
–
4828 + m * 64 +
1 ... 5
0 ... 7
Reserved
–
4828 + m * 64 +
6
0
1
2
3
4
5
6, 7
General diagnostics output channel 0
General diagnostics output channel 1
General diagnostics output channel 2
Reserved
General diagnostics module
General diagnostics failsafe protocol
Reserved
Active
Active
Active
–
Active
Active
–
4828 + m * 64 +
7
0
1
2
3 ... 7
Monitoring wire fracture output channel 0
Monitoring wire fracture output channel 1
Monitoring wire fracture output channel 2
Reserved
Inactive
Inactive
Inactive
–
4828 + m * 64 +
8 ... 21
0 ... 7
Reserved for PROFIsafe
–
Summary of Contents for 1971599
Page 2: ......
Page 75: ...Installation 2 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 2 Installation...
Page 91: ...Commissioning 3 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 3 Commissioning...
Page 112: ...3 Commissioning 3 22 Festo P BE CPX FVDA P2 EN en 1209NH English...
Page 113: ...Operation 4 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 4 Operation...
Page 143: ...Index B 1 Festo P BE CPX FVDA P2 EN en 1209NH English Appendix B Index...
Page 144: ...B Index B 2 Festo P BE CPX FVDA P2 EN en 1209NH English Table of contents B Index B 1...
Page 150: ...B Index B 8 Festo P BE CPX FVDA P2 EN en 1209NH English W Wire break 3 12 5 4...