Contents and general instructions
XI
Festo P.BE-CPX-FVDA-P2-EN en 1209NH English
–
Operation of the CPX-FVDA-P2 is permissible only in com-
bination with the following PROFIsafe-capable CPX bus
node (
bus node name plate):
CPX bus node
from Revision Network protocol
CPX-FB13
1)
30
PROFIBUS
CPX-FB33
2)
21
PROFINET IO
CPX-FB34
2)
21
PROFINET IO
CPX-FB35
2)
21
PROFINET IO
1)
Description
P.BE-CPX-FB13...
2)
Description
P.BE-CPX-PNIO...
Tab. 0/1: Permissible PROFIsafe-capable CPX bus nodes
–
Operation of the CPX-FVDA-P2 inside of CPX valve termin-
als is only permissible with the following valve types:
Valve
terminal
Type Valve types
MPA-S-FB-VI
32
MPA1, MPA2 on VMPA…-FB-EMG-…
1)
MPA-F-FB-VI
33
MPAF1, MPAF2 on VMPA…-FB-EMG-…
1)
MPA-L-FB-VI
34
All
1)
VTSA-FB-VI
44
All up to width of 52 mm
1)
VTSA-F-FB-VI
45
All up to width of 52 mm
1)
1)
If the residual current is exceeded, operative malfunctions
are possible.
Tab. 0/2: Permissible valve types
–
The operation of switch-off groups within CPX valve ter-
minals is allowed only in combination with permissible
pneumatics (
description for the respective valve ter-
minal).
Summary of Contents for 1971599
Page 2: ......
Page 75: ...Installation 2 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 2 Installation...
Page 91: ...Commissioning 3 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 3 Commissioning...
Page 112: ...3 Commissioning 3 22 Festo P BE CPX FVDA P2 EN en 1209NH English...
Page 113: ...Operation 4 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 4 Operation...
Page 143: ...Index B 1 Festo P BE CPX FVDA P2 EN en 1209NH English Appendix B Index...
Page 144: ...B Index B 2 Festo P BE CPX FVDA P2 EN en 1209NH English Table of contents B Index B 1...
Page 150: ...B Index B 8 Festo P BE CPX FVDA P2 EN en 1209NH English W Wire break 3 12 5 4...