5. Diagnostics and error handling
5-6
Festo P.BE-CPX-FVDA-P2-EN en 1209NH English
5.3
Diagnostics via LEDs
For the on-site diagnostics, the following LEDs are located
under the transparent cover of the module:
1
Module error LED
(red)
2
FP-LED (green) -
F
ailsafe
P
rotocol
3
Channel error LED
(red); one for
each output
channel
4
Status LED (yel-
low); one for each
output channel
2
1
3
4
Fig. 5/1:
LED display of the output module CPX-FVDA-P2
In the run-up phase, the error LEDs
1
and
3
light up for
approx. 500 ms.
In normal operating status, the following LEDs light up:
–
FP-LED –
F
ailsafe
P
rotocol (green)
2
–
Status LED (yellow)
4
of the active output channels
The status LED of inactive output channels and the module
1
and channel error LED
2
do not light up.
Note
The LED display of the module is not designed in a safety-
oriented way.
•
Observe that the LEDs must not be evaluated for safety-
oriented measures.
Summary of Contents for 1971599
Page 2: ......
Page 75: ...Installation 2 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 2 Installation...
Page 91: ...Commissioning 3 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 3 Commissioning...
Page 112: ...3 Commissioning 3 22 Festo P BE CPX FVDA P2 EN en 1209NH English...
Page 113: ...Operation 4 1 Festo P BE CPX FVDA P2 EN en 1209NH English Chapter 4 Operation...
Page 143: ...Index B 1 Festo P BE CPX FVDA P2 EN en 1209NH English Appendix B Index...
Page 144: ...B Index B 2 Festo P BE CPX FVDA P2 EN en 1209NH English Table of contents B Index B 1...
Page 150: ...B Index B 8 Festo P BE CPX FVDA P2 EN en 1209NH English W Wire break 3 12 5 4...