1. System overview CPX-FVDA-P2
1-23
Festo P.BE-CPX-FVDA-P2-EN en 1209NH English
1.3.1
Application ranges
Use in machines and systems with increased safety require-
ments is possible only if the safe status is achieved by switch-
ing off circuits. The following application ranges are intended:
Case Safe switch off ...
Output channel
used
Reliable function
1
... the load voltage supply for the internal
valves of the valve terminal with galvanic
isolation
CH0
Safe switch-off of the
load voltage with cyc-
lical checking of the
switch-off paths for
function and cross cir-
cuits
2
... of potential-free individual consumers
(e.g. valves, contactors, relays)
CH1 + CH2
3
... of the load voltage of external elec-
tronic consumers with safe galvanic isol-
ation of the load voltage
Tab. 1/10: Possible applications for the output module CPX-FVDA-P2