84
You can only select the statuses that are accessib le as a follow-up
status of the current status.
Further information in the chapter "Automatic assignment of RFID tags to
measuring points
".
Acceleration sensor settings
Choose sensor
: Select the sensor used from the sensor database
here.
Name of sensor position
: Enter a designation for the sensor position. This is
required for identification of the sensor by the Detector. Due to the size of the
Detector display, this name can only be five characters long.
Angle of sensor
: Enter the angle of displacement of the trigger sensor from the
zero position in the direction of rotation.. The stator is always used as the
reference for the zero position which points vertically upwards.
Trigger settings
Select trigger sensor
: Select the trigger sensor used from the sensor
here.
Name of trigger position
: Enter a name for the trigger position. This is required
by the Detector to identify the trigger sensor. Due to the size of the Detector
display, this name can only be five characters long.
Angle of trigger sensor
: Enter the angle of displacement of the trigger sensor
from the zero position in the direction of rotation.. The stator is always used as
the reference for the zero position which points vertically upwards.
Select
Positive
or
Negative
edge to indicate whether the measurement should
start on a positive or negative edge on the trigger sensor. This edge
determines the 0° position of the shaft.
Run up/coast down settings
In this section you can make settings required for Determining the resonance
range of a machine
with the run up/coast down test.
Type of vibration unit
: Enter which vibration unit to use at run up/coast down.
The following are available: Displacement, Velocity and Acceleration.
Peak setting
: Specify here whether the
peak-to-peak
value, the
peak
value or
the root mean square (
RMS
) should be evaluated.
Measurement type
: Enter whether the Detector measures during
run up
or
coast down
of the machine
54
45
45
247