139
Trendline 3
program automatically adds the .csv ("comma separated variables") extension.
Click on
OK
to export the data.
Below is a description of the contents of the export file depending on the type of
measuring point.
Measuring point from a Cm configuration
If you export a measuring point from a CM configuration, the Trendline software
saves a general export file with details of the configuration and other files with the
time signals.
The general export file contains a line for each measurement containing the
following:
Heading
Contents
idx
Measurement identification number.
State
Alarm Status: 0 – no alarm, 1 – pre-alarm, 2 – main alarm
Timestamp
Measurement timestamp.
Velocity
Ex port file w ith v elocity time signal (the signal is an acceleration signal,
see also "Time signals
").
Acceleration
Ex port file w ith the acceleration time signal.
Demodulation
Ex port file w ith the demodulation time signal.
Data x
Characteristic v alue measured
Name x
Name of characteristic v alue
Type x
Ty pe of characteristic v alue
.
Prealarm x
Pre-alarm threshold in % of the main alarm threshold.
Alarm x
Main alarm threshold.
Measuring point
Name of measuring point
export_timestamp
Ex port time
Comment
Measuring point comment
used_revolution
The rotational speed input by the user after the measurement. This v alue
is identical to the rotational speed actually measured until it is changed.
config_revolution_delta
The max imum rotational speed dev iation set in the measuring point
configuration
config_revolution
The rotational speed set in the measuring point configuration.
271
269