Profiles for TETRIX TIG and plasma systems
Profile on the Interbus Module
122
Item No.: 099-008225-EWM01
Process data
Byte
no.
Bit no.
Function
Description
0 5 Main
current
signal
Bit allocation:
0
1
Displays the status of the program sequence
Process is outside the main current phase
Process running in the main program
0 6 Process
active
Bit allocation
0
1
Signals the completion of the welding process
Process ended (after gas post-flows)
Process running
0
7
I > 0 Auxiliary process
Bit allocation:
0
1
"Current flows" signal from auxiliary process
No current flowing
Current flowing, auxiliary process active
1
0-7
Error
Error number of an error which has occurred
2 0-7
Not
used
3 0-2
User-defined
inputs
1 to 3 on bits 0 to 2
Signal status of the digital input
Logic:
0 V signal on the input = signal low
24 V on the input = signal high
4
0-7
Actual welding voltage value,
low byte
Current actual value for the welding voltage
Range: 0 to 0 x 7FFF
corresponds to 0.0 V to 100.0 V
5
0-7
Actual welding voltage value,
high byte
Current actual value for the welding voltage
6
0-7
Actual welding current value,
low byte
Current actual value for the welding current
Range: 0 to 0 x 7FFF
corresponds to 0 A to 1000 A
7
0-7
Actual welding current value,
high byte
Current actual value for the welding current
8
0-7
Actual wire feed speed value ,
low byte
Current actual value for the wire feed speed
Range: 0 to 0 x 7FFF
corresponds to 0.0 m/min to 40.0 m/min
9
0-7
Actual wire feed speed value ,
high byte
Current actual value for the wire feed speed
10
0-7
Actual motor current value
low byte
Current actual value for the motor current from the
wire feed system
Range: 0 to 0 x 7FFF
corresponds to 0.0 A to 25.5 A
11
0-7
Actual motor current value
high byte
Current actual value for the motor current from the
wire feed system
12-19 0-7
Reserved