Commissioning
Basic configuration using plug-in jumpers
Item No.: 099-008225-EWM01
13
4.1.3
Connection of fast actual value signals
The BUSINTX11 normally supplies actual process values with an update of approx. 30ms for the process
voltage, current, wire speed and motor current process values.
For seam tracking, however, fast signals are required for voltage and current. With the PHOENIX and
TETRIX, these can be provided via the interface for mechanised welding on the BUSINTX11:
Plug Pin
Signal
X7
2
Actual process voltage value
X7
3
Actual process current value
X7
4
Reference mass (GND)
NOTE
The interface for mechanised welding is supplied as standard for the PHOENIX, but not
for the TETRIX.
The use of fast actual value signals for the seam tracking is optional and must be ordered
separately!
4.1.4
Collision protection connection
A corresponding signal can be connected to the BUSINTX11 for connecting and powering a torch
collision protection signal on the field bus:
Plug Pin
Signal
X4
1
Powering an external collision contact
X4 2
Feedback
signal
from collision contact
NOTE
A separate 24V signal is used for the collision protection. It is essential to ensure that the
installation is free of short-circuits. The supply is short-circuit-proof, however the input
becomes unusable for the duration of the short-circuit.
4.2
Basic configuration using plug-in jumpers
These settings must be made before switching on the power source/external power source.
The BUSINTX11 has a series of jumpers to configure various basic settings that cannot be changed
during operation.
4.2.1
Selecting fast actual value signals
To transmit fast actual process values for voltage to use the workpiece search function, jumper JP2
should be configured as follows:
JP 2
Function
-
Actual values via system bus (factory setting)
X
Actual values are expected via plug X7
X = Jumper plugged in
4.3
Selecting the actuation profile
The profile must be selected before the power source is switched on. If the interface is supplied
with power via the external power supply, this should also be enabled for a change of profile as
well as for a shut-down of the welding power source.
Various actuation profiles are available for connection to different controls for operating BUSINTX11
independently of the field bus type, welding system and development status. These are selected using a
selector switch S1 with 16 positions.