Item No.: 099-008225-EWM01
Actuation data
Byte
no.
Bit no.
Function
Description
1 2 Reverse
inching
Bit allocation:
0
1
Signal for reverse wire inching function
Reverse inching off
Reverse inching on
1 3 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
1
4
Error reset
Acknowledgement signal for system error
1 5 User-defined
output
Bit allocation:
0
1
Switches the user-defined relay output on the bus
module
Relay not switched
Relay switched
1 6 Job
mode
Bit allocation:
0
1
Signal activates the JOB mode function
JOB mode switched off
JOB mode active
1 7 Welding
simulation
Bit allocation:
0
1
Activates the Simulate Welding function
Simulation active
Simulation off
2
0-3
Program number specification Select a program number in the range 0-15
2
7
Specification of master power
source with TANDEM
systems (optional)
Bit allocation:
0
1
Activates the master/slave power source in a
TANDEM system
System adopts slave function
System adopts master function
3
0-7
JOB number specification
Select a JOB number in the range of
1-255
4
0-7
WF specification, low-byte
Specify the wire speed in program 0
Range: 0 to 0 x 7FFF
0 corresponds to WF-MIN
0 x 7FFF corresponds to 25.0 m/min
5
0-7
WF specification, high-byte
Specify the wire speed in program 0
6 0-7
Correction
specification,
low byte
Specify the voltage correction in program 0
Range: 0 to 255
0 corresponds to -10.0 V
0 x 4000 corresponds to 0 V
0 x 7FFF corresponds to +10.0 V
7 - Correction
specification,
high byte
Specify the voltage correction in program 0
8
0-7
Dynamics specification,
low byte
Specifies the dynamic in program 0
Range: 0 to 0 x 7FFF
0 corresponds to -40
0 x 4000 corresponds to 0
0 x 7FFF corresponds to +40
9
-
Dynamics specification,
high byte
Specifies the dynamic in program 0