Profiles for TETRIX TIG and plasma systems
Profile on the Interbus Module
110
Item No.: 099-008225-EWM01
Actuation data
Byte
no.
Bit no.
Function
Description
1
3
Start auxiliary process
Bit allocation:
0
1
Start signal for the auxiliary process (plasma)
Auxiliary process off
Auxiliary process on
1
4
Error reset
Acknowledgement signal for system error
1 5 User-defined
output
Bit allocation:
0
1
Switches the user-defined relay output on the bus
module
Relay not switched
Relay switched
1 6 Job
mode
Bit allocation:
0
1
Signal activates the JOB mode function
JOB mode switched off
JOB mode active
1 7 Welding
simulation
Bit allocation:
0
1
Activates the Simulate Welding function
Simulation active
Simulation off
2 0-3
4-6
Program number specification
Reserved
Select a program number in the range 0-15
2 7 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
3
0-7
JOB number specification
Select a JOB number in the range of
1-255
4
0-7
I specification, low-byte
Specification of the welding current, the scaling is
always 100% dependent on the system current in
question:
Range: 0 to 0 x 7FFF
0 corresponds to RANGE-MIN
0 x 7FFF corresponds to the max. system current
5
0-7
I specification, high-byte
Specify the wire speed in program 0
6
0-7
WF cold wire specification,
low byte
Specification of the wire value
Range: 0 to 0 x 7FFF
0 corresponds to 0.0 m/min
0 x 7FFF corresponds to 10.0 m/min or 5.00 m/min
depending on the cold wire feed
7
0-7
WF cold wire specification,
high byte
Specifies the wire value in program 0
8-11 0-7 Reserved