Item No.: 099-008225-EWM01
Actuation data
Byte
no.
Bit no.
Function
Description
0 7 Blow-out
Bit allocation:
0
1
Manual check of the auxiliary gas
Gas supply off
Gas supply on
1 0 Inching
Bit allocation:
0
1
Signal for wire inching function on the wire feed
drive
Inching off
Inching on
1 1 Position
search
Bit allocation:
0
1
Activates the position search function for the
workpiece
Position search off
Position search on
1 2 Reverse
inching
Bit allocation:
0
1
Signal for reverse wire inching function
Reverse inching off
Reverse inching on
1 3 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
1
4
Error reset
Acknowledgement signal for system error
1 5 User-defined
output
Bit allocation:
0
1
Switches the user-defined relay output on the bus
module
Relay not switched
Relay switched
1 6 JOB
mode
Bit allocation:
0
1
Signal activates the JOB mode function
JOB mode switched off
JOB mode active
1 7 Welding
simulation
Bit allocation:
0
1
Activates the Simulate Welding function
Simulation off
Simulation active
2
0-3
Program number specification Select a program number in the range 0-15
2
7
Specification of master power
source with TANDEM
systems (optional)
Bit allocation:
0
1
Activates the master/slave power source in a
TANDEM system
System adopts slave function
System adopts master function
3
0-7
JOB number specification
Select a JOB number in the range of
1-255
4
0-7
WF specification, high-byte
Specify the wire speed in program 0
Range: 0 to 0 x 7FFF
0 corresponds to WF-MIN
0 x 7FFF corresponds to 25.0 m/min
5
0-7
WF specification, low-byte
Specify the wire speed in program 0