The diagnostics interface
PC system requirements
38
Item No.: 099-008225-EWM01
6
The diagnostics interface
To support commissioning processes and the analysis of signal sequences, the BUSINTX11 has a
diagnostics interface that is connected to a PC USB port and can be evaluated using the EWM-Analyzer
software.
6.1
PC system requirements
The following requirements must be met to operate the PC software:
• Min. 1.7 GHz CPU
• 512 MB RAM (1 GB recommended for long-term recording)
• 300 MB free hard drive space
• Min. WIN XP with Service Pack 2
6.2 Commissioning
To commission the diagnostics interface, first connect the connection cable for the PC USB port
(consisting of filter boxes SECINTX10USB, item no. 090-008190-XXXXX and connection cable PCV5-I,
item no. 094-001205-XXXXX) to the PC and the required adapter cable for connection to the 6-pole
Minifit socket X10 on the BUSINTX11 using adapter cable item no. 094-013051-XXXXX. When using a
BUSINTX11 ATCASE, the adapter cable is not necessary as the connection cable can be inserted
directly into the casing.
Jumper 6 must be inserted in position 2-3 for operation!
Start the program, use the Windows device manager to identify and set the assigned COM port.
The diagnostics are now ready for operation!
6.3 Scope
of
diagnostics
Various information can be determined using the EWM Analyzer software. In profile view, the
BUSINTX11 is displayed with the preset data profile. The relevant status of the input or output can
therefore be read off immediately (system diagnostics). For expanded signal analysis based on time,
there is a diagnostics and monitor view of the recorded data available. The current software status of the
BUSINTX11 can also be easily determined.
For more information on the Analyzer, please also see the relevant operating instructions!