Overview of jumper assignments BUSINTX11 Rev00
X15, external power supply
130
Item No.: 099-008225-EWM01
12
Overview of jumper assignments BUSINTX11 Rev00
JP No.:
Function/Meaning
Assignment
1
For internal use only, do not assign! Must not be completed
2
Fast analogue inputs
(1)
function
0 = analogue signal source is system bus
1 = analogue signal source are analogue inputs on
X7
3 Reserved
4
Activation of JOB mode
(2)
0 = JOB mode not active
1 = JOB mode active
5
Pull-up function of digital inputs
(3)
1-2 = normal signal assignment
2-3 = pull-up function, all signal pins from X4 are
connected with 15 k to 24 V
6
Diagnostic programming interface
switching
1-2 = programming interface via X2 active
2-3 = diagnostics interface via X10 active
(1)
Depending on the software version, various functions are available. In the standard software, a rapid
workpiece search is possible on the connection of Uactual on X7 with JP2 set. In the software with seam
tracking, the jumper must always be set and the analogue values must be connected to X7. From
software version 042-00897-00002, the signal source can be freely selected via JP2.
(2)
In data profiles identified with control signal operation, JP3 must not be set as otherwise it could be that
functions become blocked!
(3)
In the software version with seam tracking, this jumper must be set!