Actuation data
Byte
no.
Bit no.
Function
Description
1 4 Position
search
Bit allocation:
0
1
Activates the position search function for the
workpiece
Position search off
Position search on
Bit allocation:
0
1
Manual check via the blow-out valve
Blow-out valve off
Blow-out valve on
1
6
Check monitoring function
Bit allocation:
0
1
Activate/deactivate welding parameter monitoring
Monitoring deactivated
Monitoring activated
1 7 Welding
simulation
Bit allocation:
0
1
Activates the Simulate Welding function
Simulation off
Simulation active
2
0-3
Program number specification Select a program number in the range 0-15
2
7
Specification of master power
source with TANDEM
systems (optional)
Bit allocation:
0
1
Activates the master/slave power source in a
TANDEM system
System adopts slave function
System adopts master function
3
0-7
JOB number specification
Select a JOB number in the range of
1-255
4
0-7
WF specification, high-byte
Specify the wire speed in program 0
Range: 0 to 0 x 7FFF
0 corresponds to WF-MIN
0 x 7FFF corresponds to 25.0 m/min
5
0-7
WF specification, low-byte
Specify the wire speed in program 0
6 0-7
Correction
specification,
high byte
Specify the voltage correction in program 0
Range: 0 to 0 x 7FFF
0 corresponds to -10.0 V
0 x 4000 corresponds to 0 V
0 x 7FFF corresponds to +10.0 V
7 - Correction
specification,
low byte
Specify the voltage correction in program 0
8
0-7
Dynamics specification,
high byte
Specifies the dynamic in program 0
Range: 0 to 0 x 7FFF
0 corresponds to -40
0 x 4000 corresponds to 0
0 x 7FFF corresponds to +40
9
-
Dynamics specification,
low byte
Specifies the dynamic in program 0