270
WT.050.590.000.DE.IM.0719
Wiring Diagrams
SFC
9.
Pa.
Sheet
F
E
D
C
B
A
F
E
D
C
B
A
4
3
2
1
4
3
2
1
order number
Drawing number
Project
Norm
Checked
Drawn
Date
Name
Date
Revision
Issue
Date
Urspr.
Ers. f.
Ers. d.
GER
Prod. / Sales
Design Center
release
Date
Evoqua
Water Technologies GmbH
MBE
4
=A1
+S1
Wiring diagram
SFC
1
2
3
4
LAE5292
LAE5900.010
LAE6647
LAE7029.002
03.04.12
13.05.14
03.11.16
03.07.19
MBE
UZ
UZ
UZ
6
7593
WAE
24.10.07
20
21
22
23
24
25
26
27
28
29
30
31
20
21
22
1
2
PE
4
3
2
1
Relay-outputs A&C-Board (mother board)
(Application 1)
alarm 1
alarm 2
alarm 3
alarm 4
4
Connection from Micro 2000 / Deox 2000 Drive
Micro 2000
Deox 2000
L1
L2/N
PE
If the sensor-measuring module for Micro 2000 or
Deox 2000 is installed, the Alarm 4 output should be
used to control the drive. Alarm 4 is then no longer available
(for applications 1 and 2).
Mains voltage
Drive for Micro 2000 / Deox 2000
3-electrode cells
External voltage may
still be connected
even when the main
switch is set to OFF !
or
Sample Line dosing
Summary of Contents for WALLACE & TIERNAN SFC
Page 1: ...WALLACE TIERNAN MEASURING AND CONTROL SYSTEM SFC from version V 3 08 INSTRUCTION MANUAL...
Page 2: ...2 WT 050 590 000 DE IM 0719 SFC Please note Original instruction manual...
Page 40: ...40 WT 050 590 000 DE IM 0719 Description SFC 3...
Page 118: ...118 WT 050 590 000 DE IM 0719 Functions SFC 4...
Page 121: ...SFC Installation 5 121 Top hat rail assembly...
Page 122: ...122 WT 050 590 000 DE IM 0719 Installation SFC 5 Wall mounting assembly...
Page 123: ...SFC Installation 5 123 Top hat rail assembly...
Page 124: ...124 WT 050 590 000 DE IM 0719 Installation SFC 5 Wall mounting assembly...
Page 125: ...SFC Installation 5 125 Control cabinet installation assembly...
Page 126: ...126 WT 050 590 000 DE IM 0719 Installation SFC 5 Control cabinet installation assembly...
Page 127: ...SFC Installation 5 127 Installation of the front panel on the control cabinet...
Page 156: ...156 WT 050 590 000 DE IM 0719 Installation SFC 5...
Page 218: ...218 WT 050 590 000 DE IM 0719 Operation SFC 6...
Page 232: ...232 WT 050 590 000 DE IM 0719 Maintenance SFC 7...
Page 266: ...266 WT 050 590 000 DE IM 0719 Complete Units Retrofit Kits and Spare Parts SFC 8...
Page 274: ...274 WT 050 590 000 DE IM 0719 Declarations and certificates SFC 10...
Page 275: ...SFC Declarations and certificates 10 275 10 2 Certificate of Compliance...
Page 276: ...276 WT 050 590 000 DE IM 0719 Declarations and certificates SFC 10...
Page 284: ...284 WT 050 590 000 DE IM 0719 Settings Table SFC 11...