37
2121331-04-04/19 (Translation of the original operating instructions)
Operating Instructions
Modular Safety Control System MSC
EN
8.1.8. Modules AC-FO2 – AC-FO4
Module
AC-FO2
AC-FO4
PFH
D
(EN IEC 61508:2010)
4.09 E-9
5.84 E-9
Operating voltage
24 VDC ±20 %
Power dissipation
3 W max.
Digital OUTPUTS (no./description)
2
4
Programmable – PNP active high
OSSD (no./description)
2
4
Safe switch outputs: PNP active high – 400 mA at 24 VDC max.
Connection to MSC-CB
Via proprietary 5-way bus MSCB from EUCHNER
8.1.9. Module AH-FO4SO8
PFH
D
(IEC 61508:2010)
9.28 E-09
Operating voltage
24 VDC ± 20 %
Power dissipation
4 W max.
Current OSSD outputs
Max. 2 A per channel
Number of safety outputs (OSSD)
2 pairs (or 4 single) /static safety outputs –
PNP active high 400 mA at 24 VDC max., cat. 4
INPUT_FBK/RESTART (no./description)
4/ EDM control / automatic or manual operation possible using RESTART button
Digital OUTPUTS (no./description)
8/ programmable outputs – PNP active high
PNP active high
Response time
12 ms
Connection to MSC-CB
Via proprietary 5-way bus MSCB from EUCHNER
¨
* On the use of the module AH-FO4SO8 with output current > 500 mA, the module must be separated from the neigh-
boring modules by fitting an MSC plug connector in between.