9.2.2.11. NETWORK_IN
This function block provides the interface for a network connection input; a "1" (TRUE) is set on the OUTPUT output when
the logic level is "high", otherwise "0" (FALSE) is set.
Figure 104: NETWORK_IN
Parameter
Input Type:
Ì
Single – makes it possible to connect the signal outputs from another MSC-CB base unit.
Ì
Double – makes it possible to connect the OSSD outputs from another MSC-CB base unit.
Filter (ms): Makes it possible to filter the signals that are received from another MSC-CB base unit.
This filter can be set to between 3 and 250 ms. The time set for the filter affects the calculation of the total response time
of the module.
Important!
¨
This input can only be assigned to the base unit MSC-CB.
¨
It must be used if the
OSSD
outputs on an MSC system are connected to the inputs on a down-
stream MSC system or together with the NETWORK operator.