Modular Safety Control System MSC
EN
9.4.1.4. OR
The OR logical operator produces an output of "1" (TRUE) if at least
one of the inputs is "1" (TRUE).
IN
1
IN
2
IN
x
OUT
0
0
0
0
1
0
0
1
0
1
0
1
1
1
0
1
0
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1
Figure 142: OR
Parameter
Inputs number: You can set 2 to 8 inputs using this option.
9.4.1.5. NOR
The NOR logical operator produces an output of "0" (FALSE) if at least
one of the inputs is "1" (TRUE).
IN
1
IN
2
IN
x
OUT
0
0
0
1
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
1
Figure 143: NOR
Parameter
Inputs number: You can set 2 to 8 inputs using this option.
9.4.1.6. XOR
The XOR logical operator produces an output of "0" (FALSE) if the num-
ber of inputs that are "1" (TRUE) is even or if all inputs are "0" (FALSE).
IN
1
IN
2
IN
x
OUT
0
0
0
0
1
0
0
1
0
1
0
1
1
1
0
0
0
0
1
1
1
0
1
0
0
1
1
0
1
1
1
1
Figure 144: XOR
Parameter
Inputs number: You can set 2 to 8 inputs using this option.