11
2121331-04-04/19 (Translation of the original operating instructions)
Operating Instructions
Modular Safety Control System MSC
EN
The safety modules
AZ-FO4
and
AZ-FO4O8
have 4 separate safety relay outputs and the corresponding 4 inputs for the
external device monitoring contacts (EDM).
Two settings are available for the outputs (configuration via the software EUCHNER Safety Designer):
Ì
2 pairs of connection contacts (2 normally open contacts per output with 2 corresponding feedback loop inputs).
Ì
4 separate individual connection contacts (1 normally open contact per output with 1 corresponding feedback loop in-
put).
Only the modules
AZ-FO4O8, AH-FO4SO8
and
O8
have 8 programmable signal outputs and the module
O16
has 16
programmable signal outputs.
Using the software EUCHNER Safety Designer, complex logic can be configured using logical operators and safety functions
such as muting, timers, counters etc. defined.
All this is achieved using a straightforward, intuitive graphic user interface.
The configuration undertaken on the PC is transferred to the
MSC-CB
via a USB connection. The file is saved in the
MSC-CB
and can also be saved on the proprietary
M-A1
memory card (accessory). In this way it is possible to copy the configuration
to a different
MSC-CB
module quickly.
Important!
Ì
The MSC system is certified for the highest safety level included in the applicable industrial safety
standards (SIL 3, SILCL 3, PL e, cat. 4).
Summary of Contents for MSC
Page 1: ...EN Operating Instructions Installation and use Modular Safety Control System MSC ...
Page 171: ......
Page 173: ......