Table 72: Status table sequential muting with CURTAIN selected
SENSOR selected
S1
S2
Input
S3
S4
Muting
0
0
1
0
0
0
1
0
1
0
0
0
1
1
1
0
0
1
Muting activated
1
1
X
0
0
1
1
1
X
1
0
1
1
1
X
1
1
1
0
1
X
1
1
1
0
0
0
1
1
1
0
0
1
1
1
1
0
0
1
0
1
0
0
0
1
0
0
0
Table 73: Status table sequential muting with SENSOR selected
Blind Time:
Only with "Muting Closing = Curtain":
Should be selected if, for instance, it is known that after the end of
the muting, objects may protrude beyond the pallet and may occupy the light grid, as a result the INPUT input is set to "0"
(FALSE). During the blind time the input remains "1" (TRUE). The blind time can be between 250 ms and 1 s.