Operating Instructions
Modular Safety Control System MSC
36
(Translation of the original operating instructions) 2121331-04-04/19
8.1.3. Housing
Description
Electronics housing, 24-pin max.
Material of housing
Polyamide
Degree of protection, housing
IP 20
Degree of protection, terminal blocks
IP 2X
Fastening
Quick-release connection to rail as per EN 60715
Dimensions (H x W x D) in mm
108 x 22.5 x 114.5
8.1.4. Module MSC-CB
PFH
D
(EN IEC 61508:2010)
6.06 E-9
Operating voltage
24 VDC ±20 %
Power dissipation
3 W max.
Module enable (no./description)
2/ PNP active high "type B" as per EN 61131-2
Digital INPUTS (no./description)
8/ PNP active high as per EN 61131-2
INPUT_FBK/RESTART (no./description)
2/ EDM control/automatic or manual operation possible using RESTART button
Test OUTPUT (no./description)
4/ for checking for short circuits, overload states
Digital OUTPUTS (no./description)
2/ programmable – PNP active high
OSSD (no./description)
2 pairs/static safety outputs – PNP active high 400 mA at 24 VDC max.
Slot for the M-A1
Available
Connection to PC
USB 2.0 (Hi Speed) – cable length max.: 3 m
Connection to extension module
Via proprietary 5-way MSCB from EUCHNER
8.1.5. Module FI8FO2
PFH
D
(EN IEC 61508:2010)
5.72 E-9
Operating voltage
24 VDC ±20 %
Power dissipation
3 W max.
Digital INPUTS (no./description)
8/ PNP active high as per EN 61131-2
Test OUTPUT (no./description)
8/ for checking for short circuits, overload states
Digital OUTPUTS (no./description)
2/ programmable – PNP active high
OSSD (no./description)
2 pairs/static safety outputs – PNP active high 400 mA at 24 VDC max.
Connection to MSC-CB
Via proprietary 5-way MSCB from EUCHNER
8.1.6. Modules FI8 – FI16
Module
FI8
FI16
PFH
D
(EN IEC 61508:2010)
4.45 E-9
4.94 E-9
Operating voltage
24 VDC ±20 %
Power dissipation
3 W max.
Digital INPUTS (no./description)
8
16
PNP active high as per EN 61131-2
Test OUTPUT (no./description)
4/ for checking for short circuits, overload states
Connection to MSC-CB
Via proprietary 5-way bus MSC from EUCHNER
8.1.7. Module FM4
PFH
D
(EN IEC 61508:2010)
5.56 E-9
Operating voltage
24 VDC ±20 %
Power dissipation
3 W max.
Digital INPUTS (no./description)
12/ PNP active high as per EN 61131-2
Test OUTPUT (no./description)
8/ for checking for short circuits, overload states
Connection to MSC-CB
Via proprietary 5-way bus MSCB from EUCHNER