11 Appendix
Mycom S CPM 153
120
Hauser
PARAM
Back to
return field
Back to
return field
Data logger1/2
Meas.
value
Function off
pH/Redox K1
Display range
Min -02.00pH
Max 16.00pH
PCS time
PCS K1 off
PCS K2 off
Select
Data logger
Check
Controller
configuration
Limit functions
Chemoclean
(only with
connected system,
see below)
Select
Data logger
Measuring interval
Data logger 1 /
Data logger 2
Enter
measuring interval
00000s
(0 … 36000s)
SCS mode
SCS K1
SCS Ref. K1
SCS K2
SCS Ref. K2
off
lightk
off
Ω
lightk
Ω
C07-CPM153xx-19-06-08-en-002.EPS
PARAM
Set up 1
Controller values
Manual operation
Quick Setup
Set up 2
»Return field«:
press the PARAM
key to return to
the highlighted
fields.
= Code entry required
Back to
return field
Back to
return field
Back to
return field
+Relay: Rel. 1
–Relay: Rel. 2
Relay selection
3-point step contr.:
Motor running time
Position feedback on
L : 0,5 m
VB
L : 0,5 m
L : 1,5 m
VS
VE
Electrodes/dosing
point intervals
:
With resistance
input
Move valve to
y=100 % and
enter current
resistance
:
Control point
With segmented
Start neutral zone
End neutral zone
Optimisation point 1/2
Control point 1/2
1/2/3/4/5:
Configuration
LVS
Switch-on delay: 0 s
Switch-off delay: 0 s
Alarm
threshold: pH 16
3
:
+Relay: Rel. 1
–Relay: Rel. 2
Acid/alkali dosing
Relay selection
-point step controller
Motor running time
Position feedback on
:
100% acid
0/4 mA
20 mA
Current output 2
Assign
dosing
Relay selection
:
Relay: Rel. 1
Max.
Pulse frequency
pulse
frequency
Flowmeter
Mycom connection
Current output 2
0 ... 20 mA
4 ... 20 mA
With current input
Select range
:
y =0 ... 100 %
mA 0 ... 20
mA 20 ... 0
mA 4 ... 20
mA 20 ... 4
R
Process speed
Slow
Standard
Fast
User
(only linear)
Acid/alkali dosing
Relay selection
Max. pulse frequency
Impulsfrequenz:
Relay: Rel. 1
Flowmeter
Flow velocity
Unit
Nominal diameter
0 mA value: xxx
20 mA value: xxx
Unit
: 1/12
With current input
Move valve to
y=0 % and
enter current
resistance
:
Configuration of
external hardware:
Type
Sensors
Feedback
(Menu option
is hardware
dependent)
Characteristic
Select dosing
medium
Acid
Alkali
Note
Measurement
circuit 1 = controller
circuit 2 = look-ahead
:
Forward-looking
pH-
pH-
With resistance
input
Select range
:
0 ... 1 k
Ω
0 ... 10 k
Ω
Select characteristic
type:
linear
segmented
Select for
configuration
Limit value sensor 1
Limit value sensor 5
:
...
Selection
2 outputs
1 output
(= current output2)
Control
(when relays
current output defined)
(=2 relays)
and
Control using
Pulse length
Pulse frequency
-point step contr.
Current output
3
Assignment:
Control with
pH value circuit 1
pH value circuit 2
With resistance
input:
Move valve to
y=0 % and enter
current resistance
With linear
Start neutral zone
End neutral zone
Kr 1
2 (only 2-sided)
:
Control point
Kr
Configuration
LVS 1/2/3/4/5
Function:off
Assignm.:pH circuit 1
Switch-on pt.:pH 16
Switch-off pt.:pH 16
Control
Acid: I-length
Alkali: I-length
Dosing via
Current output 2:
0 ... 20 mA
4 ... 20 mA
single
batch/inline
dual
batch/inline
Selection of process
type:
Single batch
Dual batch
inline
Dual inline
Single
Activating Controller
function
off
on
(contr. must have been
configured)
Parameter:
Kr1: 01.00pH (only lin.)
Kr2: 01.00pH (only lin.)
Tn1:
000.0
Tn2:
000.0
Tv1:
000.0
Tv2:
000.0