9 Accessories
Mycom S CPM 153
108
Hauser
pH/redox electrodes
Rinse connection
adapter
Rinse connection adapter CPR 40 for the transport of cleaning agents for use with
retractable assemblies.
Technical Information TI 342C/07/en, Order No. 51510059
Spray cleaning system
CYR 10 / CYR 20 ChemoClean Spray Cleaning System for the transport of cleaning
agents or acids for use with retractable assemblies.
Technical Information TI 046C/07/en, Order No. 50014223
Service adapter
Optoscope
The service adapter aids communication between Hauser transmitters and
the PC using the service interface. You can use it to load new firmware and to save/write
customer data (using a PC with the Windows 95/98 or Windows NT operating system).
Terminated
pH measuring cable
•
CPK 1
: Version with pilot wire and additional outer screen, sheathed in PVC, dia.
7.2 mm. Extension with cable CYK 71 possible, see table "Measuring cable as yard
goods".
•
CPK 9
: For pH/redox electrodes with integrated temperature sensor and TOP68 plug-
in head (version ESA, ESS). Extension with cable CYK 71 possible, see table "Measu-
ring cable as yard goods".
•
CPK 12
: For IsFET pH sensors and pH/redox electrodes with integrated temperature
sensor and TOP68 plug-in head. Extension with cable CYK 12 possible, see table
"Measuring cable as yard goods".
•
Junction box VBM:
Junction box for extending measuring cable connection between
electrode and transmitter. Two screw unions for e.g. combination electrode.
Material: aluminium casting, ingress protection IP 65. Order No.50003987
•
Junction box VBA:
Junction box for extending measuring cable connection between
electrode and transmitter. Four screw unions for e.g. separate reference electrode.
Material: aluminium casting, ingress protection IP 65. Order No.50003987
Type
Properties
Applications
OrbiSint W
CPS 11/12/13
Universally applicable, very easy to clean and
insensitive to soiling due to PTFE diaphragm, pressures
up to 6 bar, conductivity > 50 µS/cm
Technical Information:
TI 028C/07/en, Order No.: 50054649
• General process engineering
• Industrial wastewater
• Detoxification (cyanide,
chrome)
• Neutralisation
CeraLiquid P
CPS 41/42/43
Electrodes with ceramic diaphragms and KCl liquid
electrolyte, use with counterpressure, explosion-proof up
to 8 bar
Technical Information:
TI 079C/07/en, Order No.: 50059346
• General process engineering
• Ultra-pure water
• Boiler feed water
• Detoxification (cyanide)
CeraGel P
CPS 71/72
Gel electrode with double-chamber reference system.
Long-term stability, short response time, very long toxic
path, resistant to alternating temperature and pressure
cycles
Technical Information:
TI 245C/07/en, Order No.: 51505837
• General process engineering
• Food processing
• Water treatment
TopHit H
CPS 401
Rupture-proof pH sensor based on IsFET technology.
Short response time, very high resistance to alternating
temperature cycles, sterilisable, almost no acid or
alkaline errors
Technical Information:
TI 283C/07/en, Order No.: 51506685
• General process engineering
• Food, pharmaceutical
applications
• Water treatment
• Biotechnology