ROC364 Instruction Manual
B-4
Local Display Panel
Rev Jun/05
LCD SUB-ASSEMBLY
WITH WINDOW
HOLES
INSIDE VIEW
OF DOOR
RTV
Figure B-5. LCD RTV Installation
7.
Position the LCD sub-assembly over the door studs and press into place.
8.
Fasten the LCD sub-assembly with the hex nuts provided in the kit.
9.
Attach the display cover to the outside of the enclosure door with the two screws provided in the
kit.
10.
Connect the display cable assembly to the display (DISPLAY) port of the ROC. Use the flat wire
clips to hold the cable in place. Make sure the cable does not interfere with the door.
B.3 Operation
B.3.1 Function
Keys
You operate the Local Display Panel with the four function keys located below the LDP. Each one of
the four keys relates to a function key label displayed above the key on the bottom line of the display
area. Table B-1 lists the labels for the keys and the functions they provide.