CAM216/16 IOM
Doc. Number: ECM-402-0116
January 2016, Rev. 1
39
Section 7: Status Information
Status Information
Table 28.
Device Status Alarms (2)
Byte
Bit
Meaning
4
7 (0x80)
Reserved for Future Use
6 (0x40)
Lost COM2 Alarm
5 (0x20)
Lost COM1 Alarm
4 (0x10)
Open Inhibit Alarm
3 (0x08)
Close Inhibit Alarm
2 (0x04)
Low Oil Level Alarm
1 (0x02)
Accumulator Charge Fault Alarm
0 (0x01)
Compatibility Error
5
7 (0x80)
Partial Stroke Test Fail Alarm
6 (0x40)
Valve Stall Alarm
5 (0x20)
Backup Power Alarm
4 (0x10)
Lost Analog Input 2
3 (0x08)
Lost Analog Input 1
2 (0x04)
Host Command ESD
1 (0x02)
Hardwired ESD Alarm
0 (0x01)
Reserved for future use
6
7 (0x80)
Not used
6 (0x40)
Not used
5 (0x20)
Function Check
4 (0x10)
Out Of Specification
3 (0x08)
Failure
2 (0x04)
Not Applicable
1 (0x02)
Device Variable
0 (0x01)
Maintenance Required
7
0 – 7
Operating Mode
8
7 (0x80)
Device Configuration Locked
6 (0x40)
Electronic Defect
5 (0x20)
Not Applicable
4 (0x10)
Power Supply Conditions Out-of-Range
3 (0x08)
Not Applicable
2 (0x04)
Not Applicable
1 (0x02)
Non-volatile Memory Defect
0 (0x01)
Not Applicable
9
7 (0x80)
Not used
6 (0x40)
Not used
5 (0x20)
Not used
4 (0x10)
Not used
3 (0x08)
Not used
2 (0x04)
Not Applicable
1 (0x02)
Not Applicable
0 (0x01)
Status Simulation Active