D
D-36
Command Line Interface
config.system.date
Syntax
date sysDate sysTime
Purpose
This command sets the system date and time.
Parameters
This command has two required parameters.
Command Examples
Root> config system date 04:16:2001 10:34:01
Root> config system date 10/09/2001 14:07:55
config.system.description
Syntax
description “systemDescription”
Purpose
This command sets the system description string.
Parameters
This command has one parameter.
Command Example
Root> config system description “DS-32M2 Fibre Channel
Switch”
sysDate
Specifies the new system date. The format of the
date parameter must be mm:dd:yyyy or
mm/dd/yyyy
. Valid date values include:
mm
: 1 through 12
dd
: 1 through 31
yyyy
: 1981 or later
sysTime
Specifies the new system time. The format of
the time parameter must be hh:mm:ss. Valid
time values include:
hh
: 0 through 23
mm
: 0 through 59
ss
: 0 through 59
systemDescription
Specifies the new system description string
for the switch. The name can contain up to
255 characters.
Summary of Contents for Connectrix DS-32M2
Page 4: ...Connectrix DS 32M2 User Guide iv ...
Page 14: ...xiv Connectrix DS 32M2 User Guide Figures ...
Page 16: ...Connectrix DS 32M2 User Guide Tables xvi ...
Page 24: ...xxiv Connectrix DS 32M2 User Guide Warnings and Cautions ...
Page 42: ...1 1 18 Connectrix DS 32M2 User Guide Switch Operating Features ...
Page 72: ...3 3 24 Connectrix DS 32M2 User Guide Product Manager Overview ...
Page 226: ...B B 8 Connectrix DS 32M2 User Guide Configuring Network Addresses ...
Page 248: ...C C 22 Connectrix DS 32M2 User Guide Configuring the Switch from a Web Server ...
Page 332: ...F F 8 Connectrix DS 32M2 User Guide Customer Support ...
Page 351: ...Connectrix DS 32M2 User Guide g 19 Glossary ...
Page 352: ...g 20 Connectrix DS 32M2 User Guide Glossary ...