A
A-24
Using SNMP to Manage the Switch
FRU Group
ef6000SysOperStatus
The current operational status of the switch. The values are defined as
follows: operational (1), redundant-failure (2), minor-failure (3), major-failure
(4), not-operational (5).
ef6000SysState
If the edOperStatus of the switchis operational, the switch is in one of the four
states: online(1), coming-online(2), offline(3), and going-offline(4).
ef6000SysAdmStatus
(read-write)
The desired administrative status of the switch. A management station may
place the switch in a desired state by setting this object accordingly. The
desired administrative statuses are online(1) and offline(2). Online means
setting the switch to be accessible by an external Fibre Channel port, and
offline means setting the switch to be inaccessible.
Table A-11
System Group (
continued
)
Variable
Provides:
Table A-12
FRU Group
Variable
Provides:
ef6000FruCode
Field replaceable unit. A hardware component of the product that is replaceable
as an entire unit. Each module defined in this MIB has a fixed FRU code. The
values are defined as follows: fru-bkplane(1) - backplane; fru-ctp(2) - control
processor card; fru-sbar(3) - serial crossbar; fru-fan2(4) - center fan module;
fru-fan(5) - fan module; fru-power(6) - power supply module; fru-reserved(7) -
reserved (not used); fru-glsl(8) - longwave, single-mode, LC connector, 1 Gig;
fru-gsml(9) - shortwave, multi-mode, LC connector, 1 Gig; fru-gxxl(10) - mixed,
LC connector, 1 Gig; fru-gsfl(11) - SFO pluggable, 1Gig; fru-gsf2(12) - SFO
pluggable, 2 Gig; fru-glsr(13) - longwave, single-mode, MT-RJ connector, 1 Gig;
fru-gsmr(14) - shortwave, multi-mode, MT-RJ connector, 1 Gig; fru-gxxr(15) -
mixed, MT-RJ connector, 1 Gig; fru-fint1(16) - F_Port, internal, 1 Gig.
ef6000FruPosition
Position of the module.
ef6000FruStatus
Operational status of the module. The active(1) state indicates that the current
module is active. The backup(2) state indicates that the backup module is used.
The update-busy (3) state indicates that the module is in the updating process.
The failed(4) state indicates that the current module is failed.
ef6000FruPartNumber
Part number of the module.
ef6000FruSerialNumber
Serial number of the module.
ef6000FruPowerOnHours
Number of the hours that the FRU has been in operation.
ef6000FruTestDate
Final test date of the module.
Summary of Contents for Connectrix DS-32M2
Page 4: ...Connectrix DS 32M2 User Guide iv ...
Page 14: ...xiv Connectrix DS 32M2 User Guide Figures ...
Page 16: ...Connectrix DS 32M2 User Guide Tables xvi ...
Page 24: ...xxiv Connectrix DS 32M2 User Guide Warnings and Cautions ...
Page 42: ...1 1 18 Connectrix DS 32M2 User Guide Switch Operating Features ...
Page 72: ...3 3 24 Connectrix DS 32M2 User Guide Product Manager Overview ...
Page 226: ...B B 8 Connectrix DS 32M2 User Guide Configuring Network Addresses ...
Page 248: ...C C 22 Connectrix DS 32M2 User Guide Configuring the Switch from a Web Server ...
Page 332: ...F F 8 Connectrix DS 32M2 User Guide Customer Support ...
Page 351: ...Connectrix DS 32M2 User Guide g 19 Glossary ...
Page 352: ...g 20 Connectrix DS 32M2 User Guide Glossary ...