• TECHNOLOGICAL Inputs
The opening of one of these inputs will activate the output programmed
as technological alarm for 1 minute and the corresponding telephone
alarm will be sent.
• FIRE input
The opening of one of these inputs will activate the output programmed
as Fire for 1 minute and the relay (if enabled for this alarm) and the
corresponding telephone alarm will be sent.
• PANIC input
An programmed SILENT PANIC input (antirobbery) will activate the
corresponding electric panic output for 1 minute. A programmed PANIC
WITH SIRENS input (antiaggression) will activate the electric panic
output and the alarm relay for 1 minute and the corresponding telephone
alarm will be sent.
2.4.3 Programming 24h active inputs
CAUTION:
An input can be programmed as LAST OUTPUT only if programmed as
delayed. By modifying the programming of an input from DELAYED to
INSTANT, the LAST OUTPUT is automatically lost if programmed.
• CHIME/GONG inputs
A burglary input programmed as CHIME/GONG will activate the output
corresponding to this signalling if the belonging sector is OFF.On the
contrary it will activate the alarm if the belonging sector is ON
EXAMPLE OF USE OF
CHIME/GONG
CM is connected to an input programmed as
GONG. CM opening
with plant OFF
activates
U2 output and will ring the buzzer of the station
and the remote keyboards for 5 seconds. CM
opening
with plant ON
generates general alarm.
CM
= microcontact (GONG input)
SHOP
CONTROL UNIT