(((ELKRON))) - MP110
4.0 USER FUNCTIONS
4.1
Change of one's code
Every operator can change his/her own code by carrying out the
following steps in sequence.
1. Enter the access code. Its correctness is confirmed by a double beep
of the buzzer or by an error beep.
2. Press key
C
**
.
The display shows character
3. Introduce the new code
The display shows flashing character
corresponding to the invitation
to introduce again the new code to be checked.
4. Introduce the new code again.
If the new code introduced for the second time corresponds to the one
introduced before, it is assumed as final and to confirm that the buzzer
generates a double confirmation beep, otherwise there is an error
signal and you leave the procedure.
Example
Main user wants to change factory
code
1
-11111. Enter
1
11111 on
keyboard and presses key
C
**
.
Introduces the new code, e.g.
1
65744. The
becomes
flashing on display ; now digits
165744 are re-entered. If the
buzzer generated a double beep
the new code has been accepted.
Note: the code first digit must be
necessarily the user identificative:
1 for MASTER code
2 for user 2
3 for the installer
4 for telesurveillant
5 for user 5
6 for user 6
7 for user 7
8 for user 8
Leds visualize respectively
the status of the following
codes:
Led on = Code enabled
Led off = Code disabled
4.2
Enabling/Disabling of
User 2, Engineer’s,
Telemonitoring and
Key Codes
1. Enter the User 1 (MASTER) code.
2. Press the
F
key, followed by the
C
**
key. The message
“ENABLE CODES” is displayed on the LCD. A flashing line appears on
the segmented display.
It is now possible to enable/disable the engineer’s code, the
telemonitoring code, the user 2 code and the key code. These 4 codes
are associated with the 4 leds present on the keypad:
ENGINEER
TELEMONITORING
USER 2
KEY CODE (EK)
3. Press the key next to the led to enable/disable the corresponding code.
4. Press the
EXIT
F
key to exit the procedure.
USERS CODE ENABLING
COD.
UT.1
EXIT
F
C
**
KEY CODE
When the CONTROL UNIT
comes out of factory the key
code is always enabled. Disabling
it makes all existing connecotrs
inoperative and turns them into
leds repeating the C.UNIT status
(ON/OFF/MON)
INSTALLER CODE
The installer code,if enabled,
remains such until the first
introduction of a user code
followed by a partial or total
activation or up to the
acknowledgement of a key.As
long as the installr is enabled
it can also connect and
disconnect
39